Not a static asset register. A living operational model of the home.
The technology behind the product, explained plainly: what the digital twin holds, how data flows, where telemetry is justified, and the documented compliance of the devices.
Eight layers. One living picture of the home.
The digital twin connects what the property is, what has happened, what is being measured, what the resident has reported and what the landlord has done.
- Verbatim EPC & UPRN provenance
- Deterministic rules engine
- Hash-chained SHA-256 audit log
Property and fabric
- UPRN and address
- Age and construction
- Fabric and insulation
- Heating and ventilation
- Floor area and exposure
Energy, affordability and flexibility
- EPC modelled demand
- Measured consumption
- Weather normalisation
- Heating behaviour
- Potential heat rationing
- Thermal affordability
- Forecast demand
- Flexibility availability
- Comfort constraints
- Flexibility outcomes
Environment and weather
- Temperature
- Relative humidity
- Carbon dioxide where appropriate
- External and forecast local weather
- Sensor health
- Measurement history
Household and support
- Resident baseline feedback
- Thermal comfort
- Support needs, shared with consent
- Contact preferences
- Signposting and referral history
Life safety
- Alarm assets
- Service life
- Replacement forecasts
- Inspections
- Open hazards
Condition and repairs
- Damp and mould reports
- Photographs
- Professional findings
- Work orders
- Repair and verification history
Compliance
- Jurisdiction
- Applicable Awaab’s Law workflow
- Risk classification
- Statutory clocks
- Written summaries
- Exceptions
Evidence and audit
- Source provenance
- Known, assumed, measured and reported status
- Timestamps
- Responsible users
- Access history
- Cryptographic verification
From sensor data to proactive action.
Evidence flows one way into a single record of each home, and out as explained risk, workflow and proof. Sensors run on their own 4G gateways or a public LoRaWAN network, never on a resident’s Wi-Fi, and the platform sits alongside your existing systems rather than replacing them.
LoRaWAN sensors
Temperature, humidity and CO₂ in the rooms where better evidence changes the decision.
Secure data ingestion
Readings stream in through managed 4G gateways or a public LoRaWAN network, independent of tenant infrastructure.
Universal hazard database
EPC data and telemetry storage held together as one living record per home.
Hybrid intelligence engine
Transparent rules and prediction produce a forward mould and cold risk forecast with the reasons attached.
Command dashboard
Risk bands, heatmap, cases and statutory clocks in one operational view.
Privacy by design
Property intelligence is kept apart from identifiable household information. Tenants opt in, and can opt out at any time, and the platform is built to support UK GDPR compliance.
Tenant and landlord outcomes
Built to support earlier intervention, faster evidenced repairs and healthier homes.
Every home gets intelligence. Sensors go where evidence matters.
Housing Guardian first builds a digital evidence baseline using information already available across the portfolio. Building science and predictive intelligence then identify where physical telemetry will materially improve investigation, prediction or verification.
Living area
Temperature · relative humidity · CO₂
Kitchen
Temperature · relative humidity
Bathroom
Temperature · relative humidity
Planning assumption
Sensor kits start from £200 per instrumented home, with a typical multi-room planning assumption of approximately £300 depending on the sensor types and how many sensors each home needs.
The economics of knowing more
Move the sliders to compare blanket hardware with telemetry placed only where evidence justifies it.
Uses the approximately £300 per home planning assumption. For budgeting, allow a range of £300 to £450 per instrumented home. Final cost depends on the sensor types, how many sensors each home needs, property layout, installation, maintenance and programme requirements.
Spend on evidence where better evidence changes the decision.
For an example portfolio of 10,000 homes, blanket hardware at £300 per home would represent £3 million before deployment specific costs. At 10 per cent it would be approximately £300,000, and at 15 per cent approximately £450,000. The appropriate telemetry proportion depends on stock, evidence quality and programme objectives.
A gateway where it pays. No gateway where it doesn’t.
Each home gets the network that suits where it is, so scattered homes are not paying for hardware built for estates.
Blocks and estates: our gateway
Where several of your homes are in one building or close together, one 4G gateway serves them all, independent of any resident’s Wi-Fi. This is the usual choice for housing associations and councils.
Homes on their own: a public network
A single home would need a gateway just for itself, so its sensors use a public LoRaWAN network instead: nothing extra to buy or fit. This is the usual choice for private landlords.
Checked on site, and after
The installer sees each sensor’s signal rated good, marginal or weak and can switch network there and then. After fitting, the signal is checked every hour, and if it stays weak a gateway is proposed for your approval.
Compliant hardware, documented device by device.
Targeted telemetry uses LoRaWAN devices supplied on the EU868 frequency plan, with 4G cellular gateways, or a public LoRaWAN network for homes on their own, so the platform never depends on a resident’s Wi-Fi. Each device listed with compliance marks is covered by a manufacturer Declaration of Conformity under the Radio Equipment Directive 2014/53/EU and RoHS, and carries the CE mark.
Indoor air and comfort sensor
Measures CO₂, temperature and humidity in the rooms where people spend time.
Manufacturer Declaration of Conformity held on file.
Sealed moisture sensor
Sealed temperature and humidity sensor for kitchens, bathrooms and cold external walls.
Manufacturer Declaration of Conformity and UKCA verification held on file.
Presence and air quality sensor
Measures CO₂, temperature, humidity, light and presence in the living room. Never fitted in bedrooms or bathrooms, for privacy.
Conformity documents being confirmed with the manufacturer before this device is listed alongside the others.
Indoor cellular gateway
Indoor LoRaWAN gateway with 4G backhaul, independent of any resident’s Wi-Fi.
Manufacturer Declaration of Conformity held on file.
Outdoor cellular gateway
Weatherproof LoRaWAN gateway with integrated 4G for external and communal locations.
Manufacturer Declaration of Conformity held on file.
Declarations of Conformity are made by the manufacturer. Copies and the UKCA verification are available in the technical and assurance pack on request.
Each home’s record stays complete and correct.
Small details decide whether a reading, a bill or a repair lands on the right home.
Solar, batteries and EV chargers
Solar panels, home batteries and EV chargers are recorded against the home even when the EPC does not show them, with who recorded it and where it came from.
Battery warnings before a sensor goes quiet
Each sensor’s battery is watched, with a low warning and a very low warning set for its make, so batteries are changed before evidence is lost.
No home counted twice
Homes are matched by UPRN, electricity meter number (MPAN), gas meter number (MPRN) or address. Possible duplicates are listed for an administrator to check. A meter shared by a block is never used to merge homes.
Live today. Ready for your homes.
Housing Guardian is in production on real homes and available now. Buy now to get started, or book a demo and see it with a sample of your own portfolio.